Sterile DiluentTo preserve cell viability and integrity, saline is resourceful sterile water. This is because of its lack of properties that can hinder tests of antibiotic susceptibility and biochemical reactions.
Concentrated sodium chloride (0.85%) introduces osmotic protection of microbial cells. Scientists use this saline water to prepare microbial suspensions when it is essential to achieve certain objectives. These objectives include delivering microbes to a test battery and to culture media for testing disk susceptibility.
They can also use normal saline water to prepare serial dilutions and stock solutions of antimicrobial agents. Bacteriostatic diluents Canada advocates for the application of 0.85% saline water to regulate murkiness of bacterial suspensions. This helps in the preservation of cell viability and integrity. They recommend isotonic sterile diluent of saline 0.45% solution.
Do not use saline if you see signs of discoloration, evaporation, contamination or any other deterioration. For this reason, store away from direct light or heat at 2 – 300. Also, avoid using it if it has expired. The expiration date here refers to the product’s intact packaging and appropriate storage.
Let trained and qualified diluent Canada experts use this bacteriostatic diluent solution for in-titro diagnosis only. More importantly, handlers must adhere to approved biohazard precautions and application procedures. For safety, consider all specimens in the laboratory as hazardous and infectious. They should therefore be handled as per standard precautions.
Procedure of use – a scientist should prepare inoculation solutions by using 1 – 5 isolated colonies to inoculate the diluents. Let him adjust the suspension to match the concentration of the required McFarland standard. The luminometer manufacturer recommends the “blanking” of each tube before inoculation.
A variation of the luminometer readings may occur due to varying thickness and quality of glass used. For this reason, experts advocate for the insertion of the tube back into the meter with the same attributes as when the researcher originally blanked the tube.
You see, sterile diluent Canada fails to support microbial growth because it lacks nutrients. However, the carry-over of nutrients may cause the growth of microbes. Evidently, the researcher needs to effectively blank each tube separately before inoculation and orient it constantly after inoculation. Failure to do this causes erroneous readings on his luminometer.